- Home
- ยป
- Our Product Range
- »
- Power Division Transformers
Power Division Transformers
Safety Isolation Transformers
Minimum Order Quantity: 1 Piece
Voltage Rating | + 5% ( NL ) |
Phase | Single Phase |
Rated Capacity | 5 kva |
Usage | An isolation transformer is a transformer used to transfer electrical power from a source of alterna,usually for safety reasons. |
Cooling Type | Dry Type/Air Cooled |
Operating Temperature Range | 0 - +- 40 degree |
- Dimensional accuracy
- Long lasting performances
- International quality
- Reasonable price
- Compact design
Specifications:
Input Voltage | rated voltage ±10% |
Output voltage | rated voltage +5% (no load) |
Efficiency | ≥95% |
Insulation resistance | ≥50MΩ |
Circumstance temp | 0--+40 degree |
DC resistance | at 25 degree 2.5Ω ± 10% |
CVT ( Constant Voltage Transformer )
Power | AC |
Brand | SUNRISE |
Material | Mild Steel |
Phase | 1 PHASE |
Primary Voltage | 230 V |
Capacity | 500 VA |
Accuracy Class | 0.5 |
Frequency | 50 HZ |
Cooling Type | Air |
We offer a wide variety of Constant Voltage Transformer( CVT) to our customers. CVT provides sufficient degree of output voltage regulation against random changes in the input voltage and load. These products are fully tested before being dispatch to our clients, to ensure superior quality and flawless performances. These products have no semiconductors or moving parts used hence very high reliability. These products are available at very reasonable price.
Features:
No semiconductors or moving parts used, hence very high reliabilityNo feedback control usedIntrinsic current limiting and short circuit protectionOutput voltage correction with ½ cycle (10 milliseconds)Full load for specified load & line variation
Specifications:
Input Voltage180 V - 260 V ACLine Frequency50 HzOutput Voltage220 / 230 V ± 1%Output Step Load Response2 cycles (30 to 40 milliseconds)Efficiency90% (approx) under full load conditionsOutput Wave FormSine waveWave from Distortion5% (approx) under full load conditionsLoad power Factor0.75% lag to 0.9% leadAmbient Temperature-10°C to 50°CTransformer TypeFerry-ResonantEffect of Frequency1.6 (approx) change in output voltage for every 1% change in line frequency
RESULT
Instantaneous Voltage Regulation. No Transient and Spikes, Sinewave output. A perfect answer and remedy for every electronic equipments voltage problems.
SPECIAL FEATURES
No semiconductors or moving parts used, hence very high reliability
No feedback control used
Intrinsic current limiting and short circuit protection
Output voltage correction with ½ cycle (10 milliseconds) from no load to full load for specified load & line variation
Short term over load capacity
Energy storage for line loss up to 3 milliseconds at typical load
Higher input voltage control range, for loads less than rated load
Very high line transient/spike rejection capability and excellent isolation characteristic
Output floating (optional)